TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 730 of 788
INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) — Continued 23. Remove four C-clip retainers (1) and backshells (2) from four leads (3). 24. Remove coupling nut (4), spring tension washer (5), retainer (6), bushing (7), nut (8), lockwasher (9), flat washer (10), and insulator washer (11) from harness (12). 25. Insert harness (12) through hole in carrier to p plate. Have h elper assist. 26. Install insulator washer (11), flat washer (10), lockwasher (9), nut (8), bushing (7), retainer (6), spring tension washer (5), and coupling nut (4) on harness (12). 27. Install four backshells (2) and C-clip retainers (1) on leads (3). 28. Attach wiring harness (13) to bracket (14) with four screws (15) and new locknuts (16). 29. Attach four leads (3) to leads (17) as follows: 509E to 509G 509F to 509H 6D POS to 6E POS 7D NEG to 7E NEG 3 0. In stall bracket (14) on carrier with fo ur screws ( 18 ) and wash ers (19 ). 0098 00-8 0098 00 TM 9-2350-261-34