TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 728 of 788
TM 9-2350-261-34 INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) — Continued 0098 00 16. R em ove tw o screws (5) and washers ( 4) from hull. 1 7. Place junction b ox ( 3) on h ull. S ecure w ith two washers (4) an d scr ews (5). TIGHTEN SCREWS TO 72-78 LB -IN (8 -9 N·M) TO R QU E. Use torque wrench (WP 0 104 0 0, I tem 57). 18. Route alarm unit cable (1) over cradle (2) and along main wiring harness. 19. Connect wiring harness (22) plug (23) to jack on bottom of junction box (5). 0098 00-6