TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 725 of 788
TM 9-2350-261-34 INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) — Continued 0098 00 4 . Rem ove fo ur screws (4) an d washers ( 3) from overhead . 5. Place alarm spare battery bracket (6) on overhead. Secure with four washers (3) and screws (4). TIGHTEN SCREWS TO 264 -2 88 LB -IN (3 0-33 N·M) TO R QUE. Use torque wrench (WP 0 104 0 0, I tem 5 8). 6. Install strap (5) on alarm spare battery bracket (6). 7 . Rem ove tw o screws (3 ) and washers ( 2) fro m left hu ll plate. 8. Install bracket (1) with two screws (3) and washers (2) to hull. 9. Inst all screw (4), tw o washers (5), and l ockn ut (6]) to bracket (1 ). 0098 00-3