Page 724 of 788
TM 9-2350-261-34 INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) — Continued 0098 00 2. Release latch (4) on each side of battery box. Lift and slide cover (5) from box. Retain cover. INSTALLATION 1. Rem ove tw o screws (1), w ashers (2), and lock nuts ( 3) fro m battery b ox cov er (4 ). D iscard lock nuts. 2. Place refill kit mounting b racket (5) on bat tery b ox c ov er (4 ). Secu re with two screws (1), washers (2), and locknuts (3). 3. Install strap assembly (6) on bracket (5). 0098 00-2