TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 719 of 788
TM 9-2350-261-34 SERVICE CHEMICAL FIRE EXTINGUISHER (M1059 ONLY) — Continued 0097 00 26. Clean gasket (8) and quad ring (9) with dry wiping rag. Inspect for cuts, breaks, wear, and elasticity. 27. Apply a thin coat of grease to gasket (8) surfaces. 28. Install gasket (8) and quad ring (9) on filler cap (10). 29. Ensure inside of shell (11) is clean and dry. Fill extinguisher with agent as required. 30. Install filler cap (10). 31. Lift puncture lever (12) and place hose (13) behind lever securing nozzle (14) in holder (15). 0097 00-7