TM 9-2350-261-34 REPLACE RF 1, 2, 3, 4 CABLE ASSEMBLIES W111, W112, W113, AND W114 (M1068 ONLY) — Continued 0093 00 NOTE Tag all cables before disconnecting them. 11. Disconnect W111 plug P1 (1) from jack J115 (2) on signal patch panel box (3). 12. Disconnect W112 plug P1 (4) from jack J116 (5) on signal patch panel box (3). 13. Disconnect W113 plug P1 (6) from jack J117 (7) on signal patch panel box (3). 14. Disconnect W114 plug P1 (8) from jack J118 (9) on signal patch panel box (3). 15. Remove cable assemblies from carrier. Have helper assist. INSTALLATION 1. Install cable assemblies in carrier. Have helper assist. 2. Push harness into base (10) of external communications box (11). Have helper assist. 0093 00-3