TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 69 of 788

TM 9-2350-261-34 PATCH PANEL BOX A10 INOPERATIVE (M1068 ONLY) — Continued 0008 00 G2Y 1. Measure resistance between cable plugs and pins on jacks of external communication box A11 as follows: W111 plug P1 (1) and pin of jack J115 (5) W112 plug P1 (2) and pin of jack J116 (6) W113 plug P1 (3) and pin of jack J117 (7) W114 plug P1 (4) and pin of jack J118 (8) 2. Does multimeter read 0 ohms for each measurement? G2YN 1. Replace cables W111, W112, W113, and/or W114 (WP 0093 00). 2. Verify no faults found. G3Y 1. Verify no faults found. 0008 00-15/16 blank