TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 687 of 788

TM 9-2350-261-34 REPAIR CURBSIDE AC POWER EXTENSION BOX A19 (M1068 ONLY) — Continued 0091 00 ASSEMBLY 1. Install six connectors (10) on cover (2) with dust caps (11) and secure with 24 screws (8) and new locknuts (9). 2. Install connector J15 (7) on extension box (4) and secure with four screws (5) and new locknuts (6). NOTE See wiring diagram (page 0091 00-4) for assembly/disassembly of wires to connectors. 3. Connect leads to connectors if necessary. 4. Install gasket (3) on extension box (4) with cover (2) and secure with four screws (1). 0091 00-3