TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 67 of 788

TM 9-2350-261-34 PATCH PANEL BOX A10 INOPERATIVE (M1068 ONLY) — Continued 0008 00 F3Y 1. Measure resistance between pins on connector J101 (1) and connector J102 (2) of external communication box A11 (3) front panel as follows: Pin 1A to pin 1A Pin 14A to pin 14A Pin 1B to pin 1B Pin 14B to pin 14B Pin 2A to pin 2A Pin 15A to pin 15A Pin 2B to pin 2B Pin 15B to pin 15B Pin 3A to pin 3A Pin 16A to pin 16A Pin 3B to pin 3B Pin 16B to pin 16B Pin 4A to pin 4A Pin 17A to pin 17A Pin 4B to pin 4B Pin 17B to pin 17B Pin 5A to pin 5A Pin 18A to pin 18A Pin 5B to pin 5B Pin 18B to pin 18B Pin 6A to pin 6A Pin 19A to pin 19A Pin 6B to pin 6B Pin 19B to pin 19B Pin 7A to pin 7A Pin 20A to pin 20A Pin 7B to pin 7B Pin 20B to pin 20B Pin 8A to pin 8A Pin 21A to pin 21A Pin 8B to pin 8B Pin 21B to pin 21B Pin 9A to pin 9A Pin 22A to pin 22A Pin 9B to pin 9B Pin 22B to pin 22B Pin 10A to pin 10A Pin 23A to pin 23A Pin 10B to pin 10B Pin 23B to pin 23B Pin 11A to pin 11A Pin 24A to pin 24A Pin 11B to pin 11B Pin 24B to pin 24B Pin 12A to pin 12A Pin 25A to pin 25A Pin 12B to pin 12B Pin 25B to pin 25B Pin 13A to pin 13A Pin 26A to pin 26A Pin 13B to pin 13B Pin 26B to pin 26B 2. Does multimeter read 0 ohms for each measurement? F3YN 1. Replace cable W117 (WP 0095 00). 2. Verify no faults found. F4Y 1. Verify no faults found. 0008 00-13