TM 9-2350-261-34 REPAIR SIGNAL PATCH PANEL BOX A10 (M1068 ONLY) — Continued 0087 00 WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. NOTE Install wires (7) on eight connectors (4) using wiring diagram (page 0087 00-6). Apply primer and sealant to threads of screws (11). 3. Install 156 jacks (8) on three jackfields (9) and secure with new lockwashers (10) and screws (11). NOTE Install two leads (12) on each jack (8) using wiring diagram (page 0087 00-6). 4. Install five connectors J135, J136, J138, J139, and J140 (13) on signal patch panel box (2) and secure with 20 screws (14) and new locknuts (15). NOTE Install wires (16) on five connectors J135, J136, J138, J139, and J140 (13), using wiring diagram (page 0087 00-6). 0087 00-4