TM 9-2350-261-34 REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES (M1068 ONLY) — Continued 0086 00 9. Connect jumper cable (1) to J1 on power supply (2) and J1 on power supply (3). 10. Connect circuits 31E and 31D leads (4) with nut (5) to positive terminal of power supply (2). 11. Connect circuits 31C (6) and 31D leads (4) with nut (5) to positive terminal of power supply (3). 12. Connect circuits 32D and 32E leads (7) with nut (5) to negative terminal on power supply (3). 13. Connect circuit 32D lead (7) with nut (5) to negative terminal of power supply (2). 14. Secure power supply (2) with four screws (9) and new lockwashers (10) on bracket (11). 15. Secure power supply (3) with four screws (9) and new lockwashers (10) on bracket (11). 0086 00-4