TM 9-2350-261-34 REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES (M1068 ONLY) — Continued 0086 00 2. Remove four screws (5) and lockwashers (6) connecting power supply (7) to bracket (8). Discard lockwashers. 3. Remove four screws (5) and lockwashers (6) connecting power supply (9) to bracket (8). Discard lockwashers. NOTE Tag all leads before disconnecting from terminals. 4. Remove four nuts (1) and five leads (2) from two power supplies (3) and (4). 5. Disconnect jumper cable (5) from two power supplies (3) and (4). 6. Remove three screws (6) and four leads (7) from power supply (3). Lift power supply (3) from enclosure. Have helper assist. 7. Remove three screws (8) and five leads (9) from power supply (4). Lift power supply from enclosure. Have helper assist. 8. Remove four screws (10), lockwashers (11), and bracket (12) from four isolators (13). Discard lockwashers. 9. Remove 16 locknuts (14), screws (15), and four isolators (13) from enclosure (16). Discard locknuts. 0086 00-2