TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 649 of 788
TM 9-2350-261-34 REPAIR POWER CONTROL ENCLOSURE, REAR PANEL (M1068 ONLY) — Continued 0085 00 19. Disconnect lead 9B (16) from terminal 51 of reversing contactor RC1 (13). 20. Disconnect leads 15A and 15B (17) from terminal 52 of reversing contactor RC1 (13). 21. Disconnect leads 17A and 17B (18) from terminal T1 of reversing contactor RC1 (13). 22. Disconnect leads 18A and 18B (19) from terminal T2 of reversing contactor RC1 (13). 0085 00-3