TM 9-2350-261-34 REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068 ONLY) — Continued 0084 00 10. Remove two screws (5), locknuts (6), washers (7), and relay XK4 (13) from left panel (9). Discard locknuts. 11. De-solder/remove four wires (10) from terminals (11) of relay XK4 (13). 12. Remove tie straps (1) from wires as required. Discard tie straps. 13. Remove 12 screws (2), locknuts (3), three connectors J24 (4), J31 (5), and J36 (7) from left panel (6). Discard locknuts. 14. Remove 16 screws (2), locknuts (3), and four connectors J30 (8), J32 (9), J33 (10), and J34 (11) from left panel (6). Discard locknuts. 15. Remove/de-solder 28 wires (12) from terminals of connectors. See wiring diagram, page 0084 00-8. 0084 00-4