TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 641 of 788

TM 9-2350-261-34 REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068 ONLY) — Continued 0084 00 NOTE Tag all leads/wires before removal for proper installation later. See wiring diagram (page 0084 00-8) for disassembly/assembly of wires/leads. 5. Remove six screws (1), lockwashers (2), and eight circuit leads (3) from terminals of relay XK2 socket (4). 6. Remove two screws (5), locknuts (6), washers (7), and relay XK5 (8) from left panel (9). Discard locknuts. 7. De-solder/remove four wires (10) from terminals (11) of relay XK5 (8). 8. Remove two screws (5), locknuts (6), washers (7), and relay XK3 (12) from left panel (9). Discard locknuts. 9. De-solder/remove five wires (10) from terminals (11) of relay XK3 (12). 0084 00-3