TM 9-2350-261-34 REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068 ONLY) — Continued 0083 00 NOTE Tag all leads and cables before removal. 4. Remove screw (1), lockwasher (2), and circuit 31A lead (3) from positive terminal of connector J25 (4). 5. Remove screw (5), lockwasher (6), and circuit 32E lead (7) from negative terminal of connector J25 (4). 6. Remove screw (8), lockwasher (9), and circuit 36C lead (10) from positive terminal of connector J26 (11). 7. Remove screw (12), lockwasher (13), and circuit 32C lead (14) from negative terminal of connector J26 (11). 8. Remove eight screws (15), locknuts (16), two dust caps (17), connector J25 (4), and connector J26 (11) from enclosure (18). Discard locknuts. 0083 00-3