TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 630 of 788
TM 9-2350-261-34 REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068 ONLY) — Continued 0083 00 2. Remove eight screws (5) and lockwashers (6) connecting power supplies (7) to bracket (8) and shift (move or slide) pow er supplies (7) to the left. Discard lockwashers. Have h elper assist. 3. Remove ten screws (9) and lockwashers (10) from faceplate (11). Lower faceplate. Discard lockwashers. 0083 00-2