TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 62 of 788

TM 9-2350-261-34 PATCH PANEL BOX A10 INOPERATIVE (M1068 ONLY) — Continued 0008 00 D2Y 1. Remove cable W124 plug P1 (1) from curbside data panel jack J3 (2). 2. Measure resistance between sockets on plug P1 (1) and pins on plug P109 (3) of cable W124 as follows: Socket A to pin A Socket N to pin N Socket B to pin B Socket P to pin P Socket C to pin C Socket R to pin R Socket D to pin D Socket S to pin S Socket E to pin E Socket T to pin T Socket F to pin F Socket U to pin U Socket G to pin G Socket V to pin V Socket H to pin H Socket W to pin W Socket J to pin J Socket X to pin X Socket K to pin K Socket Y to pin Y Socket L to pin L Socket Z to pin Z Socket M to pin M Socket a to pin a 3. Does multimeter read 0 ohms for each measurement? D2YN 1. Replace cable W124 (see your -20). 2. Verify no faults found. D3Y 1. Verify no faults found. 0008 00-8