TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 616 of 788
TM 9-2350-261-34 REPAIR AC POWER EXTENSION BOXES A6 AND A7 (M1068 ONLY) — Continued 0080 00 ASSEMBLY 1 . In stall f our co nnectors ( 1) and d ust caps (2 ) on cov er (3 ) and s ecure with 16 screws (4) and new l ockn uts (5 ). 2. Install connector J1 (6) on extension box (7) and secure with four screws (8) and new locknuts (9). 3. Connect leads to connectors if necessary. 4. Install gasket (10) and cover (3) on extension box (7) and secure with four screws (11). NOTE Color Designation for Terminals: H (HOT) = YELLOW N (NEUTRAL) = WHITE G (GROUND) = GREEN 0080 00-2