Page 611 of 788

REPLACE/REPAIR INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068 ONLY) — Continued NOTE Both inverters are removed the same way. 10. Remove three screws (1) and lockwashers (2) from mount (3) and tray (4). Discard lockwashers. 11. Remove mount (3) and inverter (5) from housing (6). Have Helper assist. 12. Remove four screws (7), washers (8), locknuts (9), and mount (3) from inverter (5). Discard locknuts. 13. Remove four screws (10), lockwashers (11), and tray (4) from four resilient mounts (12). Discard lockwashers. 14. Remove 16 screws (13), locknuts (14), 32 washers (15), and four straps (16) from tray (4). Discard locknuts. 15. Remove eight locknuts (17), washers (18), screws (19), and four resilient mounts (12) from housing (6). Discard locknuts. 16. Remove three screws (20), mounting strip (21), inverter housing (6), and retaining strip (22) from sponson. 0079 00-3 0079 00 TM 9-2350-261-34