TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 58 of 788

TM 9-2350-261-34 PATCH PANEL BOX A10 INOPERATIVE (M1068 ONLY) — Continued 0008 00 B2Y 1. Measure resistance between pins on cable W115 plug P106 ( 1) an d posts on ex tern al com m unicatio n b ox A11 (2) f ro nt pan e l a s f ollows: Post 1 (Blk) to pin A Post 1 (Red) to pin B Post 2 (Blk) to pin C Post 2 (Red) to pin D Post 3 (Blk) to pin E Post 3 (Red) to pin F Post 4 (Blk) to pin G Post 4 (Red) to pin H Post 5 (Blk) to pin J Post 5 (Red) to pin K Post 6 (Blk) to pin L Post 6 (Red) to pin M Post 7 (Blk) to pin N Post 7 (Red) to pin P Post 8 (Blk) to pin R Post 8 (Red) to pin S 2. Does multimeter read 0 ohms for each measurement? B2YN 1. Replace cable W115 (WP 0094 00). 2. Verify no faults found. B3Y 1. Verify no faults found. 0008 00-4