TM 9-2350-261-34 INSTALL ANCHOR KIT (M113A2 AND M1059 ONLY) — Continued 0073 00 8. Drill and tap ten holes as marked in Step 7. Tap holes to 1/2-13 UNC-2B, 1 inch (3 cm) minimum to 1 9/16 inch (4 cm) maximum full thread depth. 9. Install two hook brackets (1) on carrier. Secure with four screws (2). 10. Install two hooks (3) on brackets (1). Secure with two spacers (4), square nuts (5), and wingnuts (6). Stake last two threads of hook to retain wingnuts. 11. Install two supports (7) on carrier. Secure with eight flat washers (8) and screws (9). 12. Install four angle brackets (10) on carrier. Secure with eight screws (11). 0073 00-6