TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 57 of 788
TM 9-2350-261-34 PATCH PANEL BOX A10 INOPERATIVE (M1068 ONLY) — Continued 0008 00 BY 1. Remove cable W115 plug P106 (1) from patch panel box A10 jack J136 (2). NOTE Use patch cable with multimeter. See WP 0009 00 for instructions. 2. Measure resistance between 8 pairs of telephone jacks marked EXTERNAL COMM BINDING POSTS and sockets on jack J136 (2) as follows: Jack 1 (Bot) to socket A Jack 1 (Top) to socket B Jack 2 (Bot) to socket C Jack 2 (Top) to socket D Jack 3 (Bot) to socket E Jack 3 (Top) to socket F Jack 4 (Bot) to socket G Jack 4 (Top) to socket H Jack 5 (Bot) to socket J Jack 5 (Top) to socket K Jack 6 (Bot) to socket L Jack 6 (Top) to socket M Jack 7 (Bot) to socket N Jack 7 (Top) to socket P Jack 8 (Bot) to socket R Jack 8 (Top) to socket S 3. Does multimeter read 0 ohms for each measurement? BYN 1. Repair patch panel box A10 (WP 0087 00). 2. Verify no faults found. 0008 00-3