TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 518 of 788

TM 9-2350-261-34 REPLACE FUEL CONTROL VALVE — Continued 0062 00 WARNING Sparks from static electricity could cause a fire or explosion. Make sure to ground the coolant heater before you open fuel supply valve. 5. Open coolant heater fuel supply valve (WP 0059 00, WP 0060 00, or WP 0061 00). Bleed fuel hose in a suitable container. 6. After fuel flow is stable, place calibrated cubic centimeter container under fuel control valve. 7. Allow fuel to flow for exactly 1 minute then close coolant heater fuel supply valve. Container should contain 14 ± 2 cubic centimeters of fuel. 8. Repeat Steps 1 - 7 with shutoff solenoid side only of fuel control valve energized with 24 V dc. 9. Calibrated cubic centimeter glass container should now contain 8.5 ± 2 cubic centimeters of fuel. 10. If fuel flow rates are not within limits, adjust flow. Turn adjusting screw to right to increase and to left to decrease. Adjust high heat flow first, then low heat flow. 11. After fuel flow is adjusted within limits, seal adjusting screw with insulating varnish. 0062 00-4