TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 422 of 788
TM 9-2350-261-34 INSTALL ELECTRONIC EQUIPMENT HEATER KIT (M577A2 ONLY) — Continued 0058 00 37. Place electronic equipment heater fuel pump (9) on center floor support beam near rear of carrier. Secure with four washers (10), two screws (11), and two nuts (12). WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 38. Apply a thin, even coat of primer and then sealing compound to external pipe threads of adapter (13). Do not apply primer or sealing compound beyond small end of threads. 39. Install outlet elbow (14) and outlet adapter (13) on fuel pump (9). 40. Install fuel pump inlet adapter (15) on fuel pump (9). 41. Connect inlet hose (16) to inlet hose adapter (3) and inlet adapter (15). 0058 00-10