TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 408 of 788

TM 9-2350-261-34 REPAIR AUXILIARY POWER UNIT COVER (4.2 KW GENERATOR SET ONLY) (M577A2 ONLY) — Continued 0057 00 8. Check eyelets, washers, and studs. Replace parts that are bent, broken, or missing. REPAIR OR REPLACEMENT NOTE The materials used to make a cement patch are adhesive, round patch of vinyl coated nylon cloth, roller, board, wire brush, and soft bristle brush. 1. Select patch that overlaps damaged area with a margin of at least 3/4 inch (19 mm) on all sides. 2. Place board under damaged area for a flat working surface. 3. Buff patch and damaged area of fabric with wire brush. WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 0057 00-2