TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 403 of 788
INSTALL PERSONNEL HEATER KIT (M1064 ONLY) — Continued 52. Secure circuit 402 lead (6) to four weldnuts (11) with four clamps (12) and screws (13). 53. Remove screw (15) and two washers (20) securing clamp (16) and dome light lead (17) from weldnut (18). 54. Secure heater wiring harness (1), ground lead (19), clamp (16), and dome light lead (17) to weldnut (18) with screw (15) and two washers (20). FOLLOW-THROUGH STEPS 1. Open fuel shutoff cock (see your -10) and check for leaks. 2. Connect battery ground lead (see your -20). 3. Start personnel heater (see your -10) and check personnel heater installations for proper operation and leaks. 4. Turn personnel heater OFF (see your -10). 5. Install floor plates (see your -20). 6 . Raise and lo ck ram p (see yo ur -10). 7 . Stop eng ine (see yo ur -10). END OF TASK 0056 00-11/12 blank 0056 00 TM 9-2350-261-34