TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 397 of 788

TM 9-2350-261-34 INSTALL PERSONNEL HEATER KIT (M1064 ONLY) — Continued 0056 00 18. Clean external pipe threads of fittings with solvent, cleaning compound. WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 19. Apply a light coat of sealing compound to clean external pipe threads of fittings. 20. Close heater fuel shutoff valve (6). 21. Remove plug (7) from shutoff valve (6). Discard plug. 22. Install adapter (8) on shutoff valve (6). 23. Install elbow (9) on adapter (8). 24. Install personnel heater fuel hose (10) on elbow (9). 0056 00-5