TM 9-2350-261-34 REPAIR COMMANDER’S CUPOLA COVER HINGES (M113A2, M1064, AND M1059 ONLY) — Continued 0045 00 ASSEMBLY 1. Clamp or tack weld new hinge(s) (1), (2), or (3) on cover (4). Set cover on commander’s cupola. Check alignment of cover hinges with hinges on cupola. 2. Make sure hinges are aligned and spaced as shown. 3. Weld hinges to cover. See TC 9-237. Use electrode type 5356. 4. If hinge (3) has been replaced, weld in a new torsion bar cover (5). 5. Clean the weld area and apply touch-up paint to repaired area. See TM 43-0139. FOLLOW-THROUGH STEPS 1. Install commander’s cupola cover (see your -20). END OF TASK 0045 00-2