TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 297 of 788
TM 9-2350-261-34 REPAIR MULTIPIN CONNECTORS 0034 00 THIS WORK PACKAGE COVERS: Remove Receptacle (page 0034 00-1). Install Receptacle (page 0034 00-2). Remove Cable Connector (page 0034 00-2). Install Cable Connector (page 0034 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Direct Support T o o l s a n d S p e c i a l T o o l s Automotive Fuel and Electrical System Repair Tool Kit (WP 0104 00, Item 4) Digital Multimeter (WP 0104 00, Item 28) Electrical Tool Kit (WP 0104 00, Item 16) Soldering Gun (WP 0104 00, Item 22) M a t e r i a l s / P a r t s Insulation tape (WP 0105 00, Item 15) Tin alloy solder (WP 0105 00, Item 26) Contacts (as required) P e r s o n n e l R e q u i r e d Fuel and Elec Sys Rep 63G10 E q u i p m e n t C o n d i t i o n Repairable parts on workbench REMOVE RECEPTACLE NOTE Use same procedure for repairing single or multiple lead, and male or female receptacle. 1. Loosen nut (1) from receptacle (2). Slide nut back on leads (3). 2. Remove grommet (4) with contacts (5) from rear of receptacle (2). 3. Push leads (3) into grommet (4) until contacts (5) are fully exposed on other side of grommet. Clip or de-solder leads from contacts. Discard contacts. 4. Remove grommet (4) and nut (1) from leads (3). 0034 00-1