TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 258 of 788
TM 9-2350-261-34 REPLACE POWER PLANT WIRING HARNESS — Continued 0031 00 11. Connect circuit 1B lead (1) to generator field switch (2) on secondary fuel filter (3). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (see your -20). 2. Install power plant rear access panel (see your -20). 3. Start engine (see your -10). Check that power plant wiring harness works correctly. 4. Raise and lock ramp (see your -10). 5. Stop/shutdown engine (see your -10). 6. Close power plant front access door and raise trim vane (see your -10). 7. Install hull bottom access cover (see your -20). END OF TASK 0031 00-8