TM 9-2350-261-34 REPAIR FAN — Continued 0027 00 WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 11. Apply sealing compound to both sides of washer (12). 1 2. T IGH T EN N UT (11 ) TO 32 4-3 84 LB-IN ( 37-43 N·M) TO RQU E. Use torque wrench . 13. Bend one edge of washer (12) against nut (11) and on edge against fan (13). 14. Install fan housing (5) on support (10). Secure with six screws (6), two screws (7), 16 flat washers (8), and eight new locknuts (9). 15. Install cover (4) on fan housing (5). Secure with four screws (1), new lockwashers (2), and flat washers (3). FOLLOW-THROUGH STEPS 1. Install fan assembly in carrier (see your -20). END OF TASK 0027 00-6