TM 9-2350-261-34 BLOCK POWER PLANT — Continued 0015 00 WARNING Damaged slings can fail when loaded. Breaking slings can strike and injure personnel. Suspended load can fall and crush personnel. Inspect all slings before use. Do not use damaged slings. Clearly mark all damaged slings as DAMAGED - DO NOT USE. 1. Use a lifting device of at least 2,500 lb (1,135 kg) capacity and sling to lift power plant. Have helper (H) assist. 2. On level ground, place two 4 x 6 x 18 inch (10 x 15 x 46 cm) blocks (1) under front of engine. Place blocks parallel to each other with 6 inch side down. Blocks should be about 18 inches (46 cm) apart from outside edges. 3. Stack two 4 x 6 x 18 inch (10 x 15 x 46 cm) blocks (2) on top of each other. Place blocks (2) on top of blocks (1) at a 90 degree angle. Blocks will be about 10 1/2 inches (24 cm) high. 0015 00-2