TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 108 of 788
TM 9-2350-261-34 NO DC OUTPUT FROM DC POWER SUPPLY (M1068 ONLY) — Continued 0012 00 5Y 1. Measure resistance between power supply PS2 (+) OUTPUT terminal (1) and pin A2 (2) of relay K6 (3). 2. Does multimeter read 0 ohms? 5YN 1. Replace lead 31C (WP 0086 00). 2. Verify no faults found. 6Y 1. Remove cable W4 plug P1 (1) from power control enclosure jack J25 (2). 2. Measure resistance between power supply PS2 (-) OUTPUT terminal (3) and jack J25 (2) outer sleeve. 3. Does multimeter read 0 ohms? 6YN 1 . R eplace lead 3 2E ( WP 008 6 00 an d W P 00 85 00 ). 2. Install cable W4 plug P1 on pow er c ontrol e nclosure jack J25. 3. Verify no faults found. 0012 00-6