TM 9-2350-261-34 NO DC OUTPUT FROM DC POWER SUPPLY (M1068 ONLY) — Continued 0012 00 4Y 1. Remove all power from SICPS system (see your -10 and TM 11-7010-256-12&P). 2. Install all circuits on power supplies PS1 (1) and PS2 (2). 3. Measure resistance between PS1 (+) OUTPUT terminal (3) and DC bus bar at terminal 1 (4) of circuit breaker CB15 (5). 4. Does multimeter read 0 ohms? 4YN 1. Replace lead 31E (WP 0086 00 and see your -10). 2. Verify no faults found. 0012 00-5