TM 9-2350-261-20-4 REPLACE COOLANT HOSES AND FITTINGS — Continued 0646 00 3. Install tubing (8) on hose (3). Place clamp (9) on tube (8). Align clamp with sponson hole. Secure with screw (10). Wrap ends of insulated tubing with overlapping turns of insulated tape to prevent unravelling. 4. Install tubing (11) on hose (2). Wrap ends of insulated tubing with overlapping turns of insulation tape to prevent unravelling. 5. Place three clamps (12) on two hoses (2) and (3). Align clamps with bulkhead holes. Secure with three screws (13). 0646 00-8