TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 63 of 788
TM 9-2350-261-20-4 REPAIR FLAME DETECTOR SWITCH — Continued 0637 00 ASSEMBLY 1. Carefully insert ceramic rod (12) into housing (5). 2. Install bow spring (11) in mount (4). 3. Install switch (10) in mount (4) and housing (5). Be sure ceramic rod (12) fits into extension on switch. 4. Install switch (10) on mount (4) and housing (5). Secure with two screws (9), washers (8), washers (7), and nuts (6). Do not tighten. 0637 00-3