TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 583 of 788

TM 9-2350-261-20-4 REPAIR M8 CHEMICAL ALARM JUNCTION BOX (M113A2 ONLY) — Continued 0774 00 ASSEMBLY 1. Install receptacle (12), four screws (11), and new locknuts (10) on distribution box (6). 2. Install circuit breaker (3) on distribution box (6). Secure with two screws (4) and new locknuts (5). 3. Secure lead (2) to circuit breaker (3) with screw (1). 4. Install terminal board (9), screw (7), and new locknut (8) in distribution box (6). FOLLOW-THROUGH STEPS 1. Install distribution box (WP 0773 00). END OF TASK 0774 00-3/4 blank