TM 9-2350-261-20-4 REPLACE/REPAIR PORTABLE FIRE EXTINGUISHER MOUNT (M1068 ONLY) — Continued 0772 00 ASSEMBLY 1. If lining (16), (17), or (18) was removed from arm assembly (7) or (12) or bracket (8), install new lining and secure with new rivets (19). 2. Install rod end connector (11) on movable arm assembly (12) and secure with new rivet (15). 3. Install nut (14) and new lockwasher (13) on rod end connector (11). Insert connector into bracket (8) and secure with nut (10). 4. Install link (4) on fixed arm assembly (7) and secure with new rivet (9). 5. Install fixed arm assembly (7) on bracket (8) and secure with nut (5) and new lockwasher (6). 6. Install latch (3) on link (4) and secure with headed pin (2) and new cotter pin (1). 0772 00-4