TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 500 of 788

TM 9-2350-261-20-4 REPLACE CABLE W35, CABLE W28, AND CABLE ADAPTER (M1068 ONLY) — Continued 0750 00 INSTALLATION 1. Connect cable plug W35 P9 (1) to power control enclosure jack A1 J29 (2). 2. Connect cable plug W35 P1 (3) to connector adapter plug T1 P2 (4). 3. Connect cable plug W28 P1 (5) to connector adapter plug T1 P1 (6). 4. Secure cable W35 with five new tie straps (7). 5. Connect circuit 38B lead (8) to connector adapter plug T1 P3 (9). 6. Connect circuit 38B lead (10) to cable plug W28 P2 (11). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0750 00-2