TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 487 of 788

TM 9-2350-261-20-4 REPLACE CASCADE REMOTE HARNESS (M1068 ONLY) 0745 00 THIS WORK PACKAGE COVERS: Removal (page 0745 00-1). Installation (page 0745 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Locknut (4) Lockwasher (10) Lockwasher (10) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) All external power disconnected (TM 11-7010-256- 12&P) Battery ground lead disconnected (WP 0294 00) REMOVAL 1. Remove faceplate (1) on inverter housing A2 (2) by removing ten screws (3) and lockwashers (4). Discard lockwashers. 2. Loosen captive screws on connectors and disconnect RP1 harness (5) from inverters (6). 3. Remove ten screws (7), and lockwashers (8), from faceplate (9). Lower faceplate (9) to gain access to RP1 harness (5). Discard lockwashers. 4. Remove four locknuts (10), screws (11), and RP1 remote harness (5) from faceplate (9). Remove harness. Discard locknuts. 0745 00-1