TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 486 of 788

TM 9-2350-261-20-4 REPLACE AC POWER EXTENSION CABLE (W8) (M1068 ONLY) — Continued 0744 00 INSTALLATION 1. Install cable W8 in carrier. 2. Connect cable W8 plug P1 (1) to curbside power box A7 jack J1 (2). 3. Install harness W8, clamp (3), and screw (4) to hull wall. 4. Install harness W8 with five loop clamps (5) and screws (6). 5. Attach 16 new tie straps (7). 6. Connect cable W8 plug P11 (8) to power control box A1 jack J31 (9). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Turn MASTER SWITCH to ON (see your -10). Check that electrical system works properly. See TM 11-7010-256-12&P. 3. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0744 00-2