TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 470 of 788
TM 9-2350-261-20-4 REPLACE FLUORESCENT LIGHT ASSEMBLIES (M1068 ONLY) — Continued 0738 00 INSTALLATION 1. Install two fluorescent light assemblies (6), light holders (5), washers (4), and thumbscrews (3) on light holder mounts welded to overhead plate. 2. Connect fluorescent light assembly electrical connector P1 (1) to cable W11 P2 (2). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0738 00-2