TM 9-2350-261-20-4 REPLACE ELECTRONIC EQUIPMENT HEATER CONTROL BOX-TO-FUEL PUMP LEAD (M577A2 ONLY) — Continued 0632 00 INSTALLATION 1. Install two clamps (1) and five clamps (2) on circuit 402A lead (3). 2. Place two clamps (1) on two floor weldnuts. Secure with two screws (4). 3. Place lead (3) in six cradles on rear bulkhead. Secure with six clips (5). 4. Place lead (3) in ten cradles on compartment roof. Secure with ten clips (6). 5. Place five clamps (2) on forward bulkhead weldnuts. Secure with five screws (7). 6. Connect lead (3) to fuel pump lead (8). 7. Connect lead (3) to wiring harness lead (9). 0632 00-3