TM 9-2350-261-20-4 REPLACE POWER ENTRY BOX ASSEMBLY A4 (M1068 ONLY) — Continued 0737 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. If gasket (1) was removed in Step 5, cement new gasket on rear of power entry box (2). 2. Insert cables W13 (3), W14 (4), and ground lead (5) into power distribution box (6). Feed leads through rear of bulkhead. Have helper assist. 3. Install power entry box (2) on external rear bulkhead. Secure with three washers (7) and screws (8). 4. Install two cable W13 leads (3) on terminal 1 of terminal block (9). Secure with lockwasher (10) and screw (11). 5. Install two cable W14 leads (4) on terminal 2 of terminal block (9). Secure with lockwasher (10) and screw (11). 6. Install ground cable lead (5) on terminal 3 of terminal block (9). Secure with lockwasher (10) and screw (11). 7. Install lid (12) on power distribution box (6). Secure with 12 new lockwashers (13) and screws (14). 0737 00-2