TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 460 of 788

TM 9-2350-261-20-4 REPLACE AC POWER EXTENSION BOX A6 AND DC POWER EXTENSION BOX A9 AND MOUNT (M1068 ONLY) — Continued 0735 00 INSTALLATION 1. Install mount (1) on work station (2) with four washers (3) and screws (4). 2. Install two power extension boxes (5) and (6) on mount (1) with eight screws (7) and new locknuts (8). 3. Connect cable W7 (9) to connector (10) on AC power extension box (5). 4. Connect cable W45 (11) to connector (12) on DC power extension box (6). 5. Connect cable W10 (13) to connector (14) on DC power extension box (6). 6. Connect UPS cable W43 (15) to connector (16) on AC power extension box (5). 7. Connect UPS cable W42 (17) to connector (18) on DC power extension box (6). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0735 00-2