TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 459 of 788

TM 9-2350-261-20-4 REPLACE AC POWER EXTENSION BOX A6 AND DC POWER EXTENSION BOX A9 AND MOUNT (M1068 ONLY) 0735 00 THIS WORK PACKAGE COVERS: Removal (page 0735 00-1). Installation (page 0735 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Locknut (8) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) All external power disconnected (TM 11-7010-256- 12&P) Battery ground lead disconnected (WP 0294 00) REMOVAL 1. Disconnect UPS cable W42 (1) from connector (2) on DC power extension box (3). 2. Disconnect UPS cable W43 (4) from connector (5) on AC power extension box (6). 3. Disconnect cable W10 (7) from connector (8) on DC power extension box (3). 4. Disconnect cable W45 (9) from connector (10) on DC power extension box (3). 5. Disconnect cable W7 (11) from connector (12) on AC power extension box (6). 6. Remove eight locknuts (13), screws (14), and two power extension boxes (3) and (6) from mount (15). Discard locknuts. 7. Remove four screws (16), washer (17), and mount (15) from work station (18). 0735 00-1