TM 9-2350-261-20-4 REPLACE POWER CONTROL ENCLOSURE CIRCUIT 44A LEAD (M1068 ONLY) — Continued 0732 00 INSTALLATION 1. Install connector J28 (1) with lead 44A (2) in power control enclosure (3). Secure connector to right panel with four screws (4) and new locknuts (5). 2. Connect cable plug W38 P7 (6) to power Control enclosure jack J28 (1). 3. Install lead 44A (2) on terminal X1 of relay K6 (7) and secure with retained lockwasher (8) and nut (9). 4. Secure lead 44A (2) to other leads with new tie straps (10) as required. 5. Raise faceplate (11) and secure to power control enclosure (3) with ten new lockwashers (12) and screws (13). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0732 00-2