TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 449 of 788
TM 9-2350-261-20-4 REPLACE POWER CONTROL ENCLOSURE CIRCUIT 44A LEAD (M1068 ONLY) 0732 00 THIS WORK PACKAGE COVERS: Removal (page 0732 00-1). Installation (page 0732 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Locknut (4) Lockwasher (10) Tie strap (AR) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) All external power disconnected (TM 11-7010-256- 12&P) Battery ground lead disconnected (WP 0294 00) REMOVAL 1. Remove ten screws (1) and lockwashers (2), and lower faceplate (3). Discard lockwashers. 2. Remove nut (4), lockwasher (5), and lead 44A (6) from terminal X1 of relay K6 (7). Do not discard lockwasher. 3. Remove tie straps (8) holding lead 44A (6) to other leads. Discard tie straps. 4. Disconnect cable plug W38 P7 (9) from power control enclosure jack J28 (10). 5. Remove four screws (11), locknuts (12), and connector J28 (10) with lead 44A (6) from power control enclosure (13). Discard locknuts. 0732 00-1