TM 9-2350-261-20-4 REPLACE POWER CONTROL ENCLOSURE ASSEMBLY A1 (M1068 ONLY) — Continued 0731 00 INSTALLATION 1. Install power control enclosure (1) on inverter housing (2). Secure with eight washers (3) and screws (4). Have helper assist. 2. Connect all cables/connectors (5) to left/right sides of power control enclosure (1). 3. Install bracket (6) on power control enclosure (1). Secure with two new lockwashers (7) and screws (8). FOLLOW-THROUGH STEPS 1. Install cascade remote harness W15 (WP 0745 00). 2. Install roadside data panel A13 (WP 0727 00). 3. Connect battery ground lead (WP 0294 00). END OF TASK 0731 00-2